Low Pressure 1000Kg Condensing Gas Steam Boiler

Fuel gas boiler automatic instrument sets the control means are included which according to the "industrial boilers Complete supply" and provides fuel gas boiler automated instrument packages supply shall include at least the following: (1) evaporation of 4t / h and 4t / h or less boiler 1 ) detection. Water gauge, vapor pressure gauges (including saturated and superheated), water pressure gauge, water thermometer, thermometer smoke, steam flow rate calculation (including less than evaporation lt / h boiler). Oil temperature, oil pressure, oil level indication, calculates fuel (gas boiler as temperature, pressure, gas), furnace exit gas temperature indication. Evaporation of 4t / h boiler flue gas oxygen content should have, furnace pressure, temperature economizer export indication. 2) regulation. Position of formula (only for non-economizer of the boiler) or continuous feedwater automatic control, automatic adjustment of a combustion boiler the combustion of heavy oil should automatically adjust the oil temperature, air pressure gas boiler there should be automatically adjusted. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over-pressure steam indication, alarm and protection, flame protection furnace, fuel gas overpressure protection or low temperature alarm and protection. 4) Other. Auxiliary electrical control box, gas boilers should be equipped with explosion-proof electrical control equipment. (2) evaporation of 6t / h and above 6t / h boiler 1) detected. Water gauge, vapor pressure gauges (including superheated saturated), water pressure gauge, water thermometer, thermometer, smoke, water, steam pressure, water pressure indicator, calculated water flow, steam flow indication, recording and computing, oil temperature, oil pressure, oil level indication, indication and calculating the amount of oil (gas boiler as temperature, pressure, gas), economizer inlet and outlet water temperature indication, furnace exit gas temperature, exhaust gas temperature, air pressure, furnace pressure indication, Sheng Mei an inlet, an outlet indicated negative, indicating flue gas oxygen content, there is an outlet air temperature should be indicative of the boiler air preheater, the boiler superheater, there should be recorded and the superheated steam temperature indication. 2) regulation. Continuous automatic adjustment of water supply, drum, induced draft fan damper flap opening remote control, remote pump control valve (an intake gas boiler control valve), a heavy oil combustion boiler should automatically adjust the oil, gas boiler should automatically adjust the air pressure, there is superheater boiler there should automatically adjust the temperature of superheated steam. 3) alarm and protection. High and low water level indication and alarm, low water level limit protection, over voltage protection and alarm indication of heart steam, oil accident alarm system, furnace flame protection, fuel gas overpressure protection or low temperature alarm and protection. Boiler superheater should have more limited temperature of superheated steam and an alarm indication. 4) control and the other. Drums, Fan, and start and stop the pump interlock control program, drum, fan baffle opening damper indicated, shall be provided with explosion-gas boiler electrical control equipment.

The main reason gas low pressure 1000kg condensing steam boiler produces smoke which fuel gas steam boiler main cause of smoke. A fuel gas steam boiler: oil, gas oil quality is not good when the gas contains more water, reduce the heat value of the fuel, while producing steam, the furnace temperature tends to decrease, making it difficult to burn, easy to produce smoke. Water and more oil, mainly when unloading rain water into the oil during heating the oil in water vapor penetration. When the oil contains impurities, the impurities unburned produce fine coke, the coke into fine smoke, dust becomes large, and the formation of soot. Impurities contained in the oil and gas, but also affect the pure oil and pure combustion gas generated soot. Oil impurities, mainly due to inappropriate choice of filters or filter difference impurity removal effect. Second, the failure of the fuel atomizing nozzle member main burner fuel oil atomizing nozzle. Atomizing oil burner nozzle fails, affecting the quality of the atomization, easy to poor combustion. 1, the adhesiveness between the bonding surface of the oil and the consequences of failure oil atomizers swirl atomizers and the splitter plate well, leakage will occur, atomized large oil particles, increasing the amount of fuel injection and the like. In this case serious deterioration of the quality of the combustion, the oil droplets have landed on the water wall, stacking up oil coke, partially unburned black smoke into droplets. The tangential swirl chip groove clogging mist causes uneven density distribution in the dense side of the oil mist, combustion air be insufficient. In the more dilute side of the oil mist, combustion air causes severe local excess. Mixed with oil, wind conditions deteriorated significantly, combustion conditions deteriorate, resulting in black smoke. 2, spray atomization slice failure and the consequences of failure to clogging and wear. Nozzle clogging, resulting in blockage of the fuel injection quantity is not glib increase, oil particle size thicker, the effect of fuel poor and black smoke. Wear injection port, a large hole diameter, increasing the amount of fuel injection, increasing the particle size of oil affect combustion efficiency, produce black smoke. The use of artificial gas burner, naphthalene and tar and other impurities will block the nozzles, the influence of gas distribution, resulting in black smoke. Should therefore be cleaned regularly, or clogging of the selected burner. 3, the partition partitioning poor poor, insufficient supply of air into and excess. The amount of air can not meet the requirements of the fuel combustion, so that combustion of fuel can not be sufficiently black smoke. The amount of air, will result in lower combustion temperature, black smoke and fuel difficult to burn. 4, the furnace temperature is too low when starting the furnace, fuel oil steam boiler furnace temperature is too low due to easy black smoke. 5, the furnace hearth product oil is sometimes caused by internal combustion nozzle oil accumulated inside the chamber, the oil reservoir coke black smoke at high temperature. Causes dripping of fuel combustion nozzle: ① The drip just work, just at the operating pressure is too low, the oil will flow from the nozzle, instead of the discharge. The reason for low oil pressure is a solenoid valve, the valve is clogged filter or the like or failure caused by contamination. ② In the dripping process work, probably because the relative position of burner nozzle mounting head too far, improper ignition electrode position, the oil into the atomizer, the nozzle holder is mounted is not tight, nozzle dirty, low oil pressure caused. ③ When the dripping stopped, because the line between the pump and the air nozzle, electromagnetic valve or a hydraulic valve or dirty failure. 6, the furnace flue purged countless consequences when the furnace flue remnants of oil and gas, when gas purging endless, high temperatures encountered in the explosion and black smoke. 7, the furnace smoke, sparks, the furnace pressure is too ①; ② inappropriate choice of the burner, the burner flame is too long or too much power; ③ improper combustion ratio, there are more to produce products of incomplete combustion; ④ atomization quality is not good nozzle or improper installation location, or affect the combustion flame into the furnace off port; ⑤ flue is blocked, poor smoke; ⑥ a secondary air mismatches; irrational ⑦ furnace structure; ⑧ oil spray angle is selected from with improper.

Fast boiler particularly strong technical team, they listened carefully to our needs and give us tailored technology solutions, from boiler production, transport to the site installation and commissioning took only 35 days time, all aspects of the deal in place, the boiler quickly it is put into use. --customer feedback

First, when the flue temperature dropped to below 50 ℃ Solution: Check the tail may enter the flue if heated, while the flue thoroughly remove soot. No burning flue tail, can be re-started ignition; if burning, should be replaced, repaired burning member. Second, the combustion chamber when the negative pressure is too large Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C over 1 hour and stable, open the inspection hole inspection; after inspection after confirming the fire source, before start the fan ventilation. Third, shutdown or fire, air gun valve ajar solutions: reinforcing and electric low pressure 1000kg condensing steam boiler feed water drainage, or open the valve economizer recirculation tube to protect the economizer is not burning. Fourth, Kai, during shutdown lower furnace temperature, a solution of unburned fuel in the furnace: extinguishing device immediately put into vapor, carbon dioxide or other devices off fire. Five burning improperly adjusted, with insufficient wind or with the wind unreasonable Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan. These are the methods of electric heating steam boiler fast boiler to provide you with the handling of soot in the chimney, if you use electric steam boilers, with more than five can control their own boiler equipment need to be cleared up the flue, and select the appropriate method .

Low Pressure 1000Kg Condensing Gas Steam Boiler Related Information

1000 kg gas fired steam boiler - twist-communicatie.nl

4000kg hr steam boiler - albers-restaurant.de. 1000kg/hr steam boiler with burner Gas Central Oil gas dual fuel steam boiler 1000kg/hr 2000kg/hr 3000kg/hr 4000kg/hr,US $ 5,000 2.0.35-14MW hot water 300KW biomass sawdust burner for steam boiler, 1000 kg hr Natural Gas Low Pressure Steam Boiler

Get a Quote

1000Kg Electric Steam Boiler -

1000kg Electric Steam Boiler. 1000kg wood chip boiler - imperialhotel.in. 1000kg steam boiler. 1000kg steam boiler, Diesel Oil Fired Steam Boiler for industry this is our Côte d'Ivoire's customer,he bought one set of 8ton biomass steam boiler from our company in 2013,during these 3 years from 2013-2016,the boiler's running situation is

Get a Quote

200 kg h low pressure steam boiler - darbouche

2019-2-28 · Low pressure steam boiler, three pass reverse flame, with efficiency from 91% up to 97%(1) according the installed smoke tube (STD, HPO, HP). BAHR'UNO is a family of packaged smoke tube steam boilers, three pass reverse flame, wet back. Standard safety pressure up to 0.98 bar and output from 140 to 4000 kg/h.

Get a Quote

A Guide to the Different Types of Boilers for Industrial

In the meantime, use the following information to for an overview of the different types of boilers. Firetube Boilers. If your facility has hot water applications, high-pressure steam applications, or low-pressure steam applications, you may able to utilize a non-condensing firetube boiler.

Get a Quote

High Efficiency 1.0 Ton Low Pressure Wood Chip

High Efficiency 1.0 Ton Low Pressure Wood Chip Steam Boiler For Machinery Industry, Find Complete Details about High Efficiency 1.0 Ton Low Pressure Wood Chip Steam Boiler For Machinery Industry,1.0 Ton Steam Boiler,Low Pressure Steam Boiler,Wood Chip Boiler from Boilers Supplier or Manufacturer-Henan Swet Boiler Co., Ltd.

Get a Quote

High Efficiency Steam Boilers - Burnham Commercial

High Efficiency Steam Boilers By combining Burnham Commercial steel boilers with our flue gas economizer, additional heat can be drawn out of the economizer and used to pre-heat the water coming back to the boiler.

Get a Quote

40 ton diesel steam boiler price ZOZEN Boiler

Let your boiler operate more efficiently and economically Low Fuel Consumption 50kg-1000kg/Hr Gas/Diesel Oil Steam Boiler US$3,500.00-US$12,000.00 / Set

Get a Quote

Low Pressure 500kg/h 1000kg/h 1500kg/h Gas Oil

Low Pressure 500kg/h 1000kg/h 1500kg/h Gas Oil Steam Boiler Suppliers For Fermentor, Find Complete Details about Low Pressure 500kg/h 1000kg/h 1500kg/h Gas Oil Steam Boiler Suppliers For Fermentor,500kg/h 1000kg/h 1500kg/h Gas Oil Steam Boiler,500kg/h 1000kg/h 1500kg/h Oil Steam Boiler,500kg/h 1000kg/h 1500kg/h Gas Steam Boiler from Boilers Supplier or Manufacturer-Henan

Get a Quote

Cleaver-Brooks Commercial and Industrial Boilers

2019-11-1 · 500 to 12,000 MBTU in full-condensing and near-condensing hydronic boilers, and 10 to 80 horsepower commercial steam boilers to fit almost any application. Heat Recovery Steam Generator State-of-the-art, customized, packaged heat-recovery steam generators with turbines from 1 to 45 MW.

Get a Quote

oil gas boilers and low pressure

water heaters intended for low-pressure service that are directly fired by oil, gas, electricity, coal, or other solid or liquid fuels (2). These are steam boilers in which the steam pressure does not exceed 15 psi, and water boilers in which the pressure does not exceed 160 psi and temperature does not exceed 250°F. [email protected] > Get A

Get a Quote

Cleaver-Brooks Commercial and Industrial Boilers

2019-11-1 · 500 to 12,000 MBTU in full-condensing and near-condensing hydronic boilers, and 10 to 80 horsepower commercial steam boilers to fit almost any application. Heat Recovery Steam Generator State-of-the-art, customized, packaged heat-recovery steam generators with turbines from 1 to 45 MW.

Get a Quote

2 ton 3 ton steam boiler -coal steam boiler Coal Fired

PBS Energo - Low-pressure condensing turbines. The low-pressure condensing turbines are often installed on the steam side in series downstream of the existing steam back-pressure turbines. Such arrangement brings Steam turbine - Wikipedia. A 2017 Best Selling 4 Ton Xinda Steam Boiler

Get a Quote

1000 kg gas boiler - dm-psp-tubes.be

BR-GSG-1000 Boiler room with the Gas steam-generato. Description Boiler room equipped with the automatic gas steam-generator GSG-1000 with power 700 kW (from 500 to 1000 kg of hot steam per hour), steam pressure in range from 1 to 16 bar Fully equipped boiler room with the

Get a Quote

Gas Fire Steam Boiler Calculation - hotel-restaurant

Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure. Plc Auto Control 1000kg Condensing Gas Fire

Get a Quote

oil gas boilers and low pressure

water heaters intended for low-pressure service that are directly fired by oil, gas, electricity, coal, or other solid or liquid fuels (2). These are steam boilers in which the steam pressure does not exceed 15 psi, and water boilers in which the pressure does not exceed 160 psi and temperature does not exceed 250°F. [email protected] > Get A

Get a Quote

Do You Want To Get An Exclusive Project Plan ?

7 * 24 * 365 endless service, click the button to provide you with professional and fast solutions at any time

Scroll to Top